Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Cancer Imaging ; 22(1): 53, 2022 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-36138437

RESUMEN

AIM: To compare [68Ga]PSMA-11 PET-CT, [68Ga]PSMA-11 PET-MRI and MRI in a cohort of prostate cancer (PCa) patients in biochemical recurrence after initial curative therapy. MATERIALS AND METHODS: Fifty-three patients with biochemically recurrent PCa underwent whole-body [68Ga]PSMA-11 PET-CT 1 hour post-injection (p.i.) followed by [68Ga]PSMA-11 PET-MRI 2.5 hours p.i., including a multiparametric MRI pelvic protocol examination. Imaging data analysis consisted of visual (qualitative) evaluation of the PET-CT, PET-MRI and MRI scans, as well as semi-quantitative and quantitative analyses of the PET and MRI data, including calculation of the parameters standardized uptake value (SUV) and apparent diffusion coefficient (ADC) derived from the PCa lesions. Association analysis was performed between imaging and clinical data, including PSA level and Gleason score. The results were considered significant for p-values less than 0.05 (p < 0.05). RESULTS: The hybrid imaging modalities [68Ga]PSMA-11 PET-CT and PET-MRI were positive in more patients than MRI alone. In particular, PET-CT detected lesions suggestive of PCa relapse in 34/53 (64.2%), PET-MRI in 36/53 (67.9%) and MRI in 23/53 patients (43.4%). While no significant differences in lesion detection rate were observed between PET-CT and PET-MRI, the latter was particularly efficient in detection of local recurrences in the prostate bed mainly due to the contribution of the MRI part of the modality. Association analysis revealed a statistically significant increase in the probability of a positive scan with increasing PSA levels for all imaging modalities. Accordingly, there was no significant association between scan positivity rate and Gleason score for any imaging modality. No significant correlation was observed between SUV and ADC values in lymph node metastases. CONCLUSION: [68Ga]PSMA-11 PET-CT and PET-MRI provide equally good detection rates for PCa recurrence, both outperforming stand-alone MRI.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Ácido Edético , Radioisótopos de Galio , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Imagen Multimodal , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Antígeno Prostático Específico , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología
2.
J Magn Reson ; 341: 107259, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35779309

RESUMEN

In quantitative susceptibility mapping, the tissue susceptibility is determined from the magnitude and phase of the gradient echo signal, which is influenced by the interplay of complex susceptibility and diffusion effect. Herein, we analytically analyze the influence of diffusion on magnitude and phase images generated by randomly arranged magnetic spheres as a model of intracerebral iron depositions. We demonstrate that both gradient and spin echo relaxation rate constants have a strong and nonlinear dependence on diffusion strength and give empirical formulas for magnitude and phase. This may be used in the future to improve QSM processing methods. In addition, we show that, in theory, combined acquisitions of gradient and spin echo can be used to determine the dimension of the magnetic spheres and the diffusion strength.


Asunto(s)
Mapeo Encefálico , Imagen por Resonancia Magnética , Encéfalo , Mapeo Encefálico/métodos , Difusión , Fenómenos Magnéticos , Imagen por Resonancia Magnética/métodos
3.
Phys Rev E ; 104(3-1): 034419, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34654209

RESUMEN

Determination of the spin echo signal evolution and of transverse relaxation rates is of high importance for microstructural modeling of muscle tissue in magnetic resonance imaging. So far, numerically exact solutions for the NMR signal dynamics in muscle tissue models have been reported only for the gradient echo free induction decay, with spin echo problems usually solved by approximate methods. In this work, we modeled the spin echo signal numerically exact by discretizing the radial dimension of the Bloch-Torrey equation and expanding the angular dependency in terms of even Chebyshev polynomials. This allows us to express the time dependence of the local magnetization as a closed-form matrix expression. Using this method, we were able to accurately capture the spin echo local and total magnetization dynamics. The obtained transverse relaxation rates showed a high concordance with random walker and finite-element simulations. We could demonstrate that in cases of smaller diffusion coefficients, the commonly used strong collision approximation significantly underestimates the true value considerably. Instead, the limiting behavior in this regime is correctly described either by the full solution or by the slow diffusion approximation. Experimentally measured transverse relaxation rates of a mouse limb muscle showed an angular dependence in accordance with the theoretical prediction.

4.
Eur Radiol ; 31(9): 6631-6639, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33713171

RESUMEN

OBJECTIVE: To evaluate the dual-energy (DE) performance and spectral separation with respect to iodine imaging in a photon-counting CT (PCCT) and compare it to dual-source CT (DSCT) DE imaging. METHODS: A semi-anthropomorphic phantom extendable with fat rings equipped with iodine vials is measured in an experimental PCCT. The system comprises a PC detector with two energy bins (20 keV, T) and (T, eU) with threshold T and tube voltage U. Measurements using the PCCT are performed at all available tube voltages (80 to 140 kV) and threshold settings (50-90 keV). Further measurements are performed using a conventional energy-integrating DSCT. Spectral separation is quantified as the relative contrast media ratio R between the energy bins and low/high images. Image noise and dose-normalized contrast-to-noise ratio (CNRD) are evaluated in resulting iodine images. All results are validated in a post-mortem angiography study. RESULTS: R of the PC detector varies between 1.2 and 2.6 and increases with higher thresholds and higher tube voltage. Reference R of the EI DSCT is found as 2.20 on average overall phantoms. Maximum CNRD in iodine images is found for T = 60/65/70/70 keV for 80/100/120/140 kV. The highest CNRD of the PCCT is obtained using 140 kV and is decreasing with decreasing tube voltage. All results could be confirmed in the post-mortem angiography study. CONCLUSION: Intrinsically acquired DE data are able to provide iodine images similar to conventional DSCT. However, PCCT thresholds should be chosen with respect to tube voltage to maximize image quality in retrospectively derived image sets. KEY POINTS: • Photon-counting CT allows for the computation of iodine images with similar quality compared to conventional dual-source dual-energy CT. • Thresholds should be chosen as a function of the tube voltage to maximize iodine contrast-to-noise ratio in derived image sets. • Image quality of retrospectively computed image sets can be maximized using optimized threshold settings.


Asunto(s)
Yodo , Humanos , Fantasmas de Imagen , Fotones , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
5.
Radiologe ; 61(Suppl 1): 1-10, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33598788

RESUMEN

Over the last decade, a fundamentally new type of computed tomography (CT) detectors has proved its superior capabilities in both physical and preclinical evaluations and is now approaching the stage of clinical practice. These detectors are able to discriminate single photons and quantify their energy and are hence called photon-counting detectors. Among the promising benefits of this technology are improved radiation dose efficiency, increased contrast-to-noise ratio, reduced metal artifacts, improved spatial resolution, simultaneous multi-energy acquisitions, and the prospect of multi-phase imaging within a single acquisition using multiple contrast agents. Taking the conventional energy-integrating detectors as a reference, the authors demonstrate the technical principles of this new technology and provide phantom and patient images acquired by a whole-body photon-counting CT. These images serve as a basis for discussing the potential future of clinical CT.


Asunto(s)
Fotones , Física , Humanos , Tomografía , Tomografía Computarizada por Rayos X
6.
NPJ Breast Cancer ; 7(1): 3, 2021 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-33398008

RESUMEN

Conventional CT scanners use energy-integrating detectors (EIDs). Photon-counting detector (PCD) computed tomography (CT) utilizes a CT detector technology based on smaller detector pixels capable of counting single photons and in addition discriminating their energy. Goal of this study was to explore the potential of higher spatial resolution for imaging of bone metastases. Four female patients with histologically confirmed breast cancer and bone metastases were included between July and October 2019. All patients underwent conventional EID CT scans followed by a high resolution non-contrast experimental PCD CT scan. Ultra-high resolution (UHR) reconstruction kernels were used to reconstruct axial slices with voxel sizes of 0.3 mm × 0.3 mm (inplane) × 1 mm (z-direction). Four radiologists blinded for patient identity assessed the images and compared the quality to conventional CT using a qualitative Likert scale. In this case series, we present images of bone metastases in breast cancer patients using an experimental PCD CT scanner and ultra-high-resolution kernels. A tendency to both a smaller inter-reader variability in the structural assessment of lesion sizes and in the readers' opinion to an improved visualization of lesion margins and content was observed. In conclusion, while further studies are warranted, PCD CT has a high potential for therapy monitoring in breast cancer.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...